SY35U Excavator OMM
Replace the Primary Fuel Filter/Water Separator Element
R
WARNING!
• Components and oil remain hot when the engine is stopped and may cause severe burns.
Wait until components and oil are cool before you proceed.
• Never service the fuel system near an open flame or while smoking.
• Fuel that comes into contact with hot surfaces or electrical components can cause a fire.
Clean up any fuel spills immediately.
Failure to follow these warnings could result in death or serious injury.
NOTICE!
• Cleanliness is important when working with an open fuel system.
• Dispose of fuel and filters according to all applicable environmental regulations.
Failure to follow this notice could damage the machine, cause it to operate improperly, or
damage the environment.
1. Prepare the machine for service. See "Maintenance Safety" on page 2-8.
2. Open the right rear access door. See "Opening the Right Rear Access Door" on page 5-26.
3. Turn the battery disconnect switch to OFF. See "Battery Disconnect Switch" on page 3-31.
4. Drain the primary fuel filter. See "Check and Drain the Primary Fuel Filter/Water Separator" on page 4-10.
SANY
Operation and Maintenance Manual — 0120
Maintenance
5-49
Need help?
Do you have a question about the SY35U and is the answer not in the manual?