Annually Or Every 4000 Hours; After Maintenance Is Completed; Hydraulic Breaker Maintenance Interval - SANY SY35U Operation And Maintenance Manual

Table of Contents

Advertisement

Maintenance
Check the engine valve clearance. (Contact a SANY dealer for information.)
Inspect the alternator. (See page 5-36.)
Inspect the starter. (See page 5-37.)
Clean the hydraulic oil suction strainer. (See page 5-62.)
Change the hydraulic oil. (See page 5-63.)
Change the final drive oil. (See page 5-73.)

Annually or Every 4000 Hours

Check the air conditioner compressor function and look for leaks. (See page 5-43.)

After Maintenance is Completed

Record the completion of all of the maintenance tasks in the Maintenance Log. If authorized, remove all lockout/
tagout warnings and machine-securing elements and fully activate the machine. Return the machine to operation.

Hydraulic Breaker Maintenance Interval

Hydraulic oil breaks down faster on machines equipped
with a hydraulic breaker than on machines equipped with a
bucket. Follow the steps below to set the service intervals:
1. Initial hydraulic filter maintenance must be carried out
after the first 100 hours.
2. Hydraulic oil return filter must be replaced every 250
hours with a breaker operating rate above 50%.
3. Change the hydraulic oil according to the change
interval shown in the chart.
5-18
Operation and Maintenance Manual — 0120
SY35U Excavator OMM
Fig. 5-1
0001636