Machine Operation
Air Conditioner Storage
When the air conditioner will not be used for an extended period of time, it should be operated for 3 to 5 minutes
each month to lubricate the compressor components and air conditioning system seals.
Removing from Storage
NOTICE!
If the machine was not operated monthly, contact a SANY dealer. Failure to follow this notice
could damage the machine or cause it to operate improperly.
Follow the procedures below before using a machine that has been stored for a prolonged period of time:
•
Clean the grease from the hydraulic cylinder rods.
•
Add oil or apply lubricant to all parts or components.
•
Check fluid levels.
•
Drain the water and sediment from the fuel water separator. See "Check and Drain the Primary Fuel Filter/
Water Separator" on page 4-10.
Starting the Engine After Long-Term Storage
NOTE: The illustration shows a cab machine. Canopy machines are similar.
1. Insert the key and turn the key switch (1) to ON.
2. Turn the throttle control dial (2) to the MAX (high idle)
position for 3 seconds.
3. Turn the throttle control dial (2) to the MIN (low idle)
position and start the engine. See "Starting the Engine"
on page 4-16.
4-50
Operation and Maintenance Manual — 0120
SY35U Excavator OMM
Fig. 4-66
1
2
0002782