Parameters That Change From The Default Settings With E3-01; Mode Selection] - YASKAWA CR700 Technical Manual

Hide thumbs Also See for CR700:
Table of Contents

Advertisement

10.18 Parameters that Change from the Default Settings with E3-01 [Motor 2 Control Mode Selection]
10.18 Parameters that Change from the Default Settings with
E3-01 [Motor 2 Control Mode Selection]
The values for the parameters in these tables depend on the values for parameter E3-01. When you change E3-01,
the default settings will change.
No.
Name
Motor 2 Slip
C3-21
Compensation Gain
Motor 2 Slip Comp
C3-22
Delay Time
M2 Torque Comp Delay
C4-08
Time
M2 Torque Comp Delay
C4-14
Time Sel 1
Motor 2 ASR
C5-21
Proportional Gain 1 (P)
Motor 2 ASR Integral
C5-22
Time 1 (I)
Motor 2 ASR
C5-23
Proportional Gain 2 (P)
Motor 2 ASR Integral
C5-24
Time 2 (I)
Motor 2 ASR Delay
C5-26
Time
Motor 2 Maximum
E3-04
Output Frequency
Motor 2 Maximum
E3-05
Output Voltage
E3-06
Motor 2 Base Frequency
Motor 2 Mid Point A
E3-07
Frequency
Motor 2 Mid Point A
E3-08
Voltage
Motor 2 Minimum
E3-09
Output Frequency
Motor 2 Minimum
E3-10
Output Voltage
Motor 2 Mid Point B
E3-11
Frequency
Motor 2 Mid Point B
E3-12
Voltage
E3-13
Motor 2 Base Voltage
M2 Middle Out Freq Volt
E3-14
Select
M2 Minimum Out Freq
E3-15
Volt Select
Motor2 Brake Delay
S1-25
Frequency
Motor2 Brake Delay
S1-26
Time
Motor2 Torque
S1-31
Compensation (FWD)
Motor2 Slip Prevention
S1-36
Frequency
Motor2 Slip Prevention
S1-37
Time
*1
This is the value for 200 V class drives. Double the value for 400 V class drives.
554
Range
Unit
0.0 - 2.50
0.1
0 - 10000
1 ms
0 - 60000
1 ms
0 - 60000
1 ms
0.00 - 300.00
0.01
0.000 - 10.000
0.001 s
0.00 - 300.00
0.01
0.000 - 10.000
0.001 s
0.000 - 0.500
0.001 s
40.0 - 590.0
0.1 Hz
*1
0.0 - 255.0
0.1 V
0.0 - 590.0
0.1 Hz
0.0 - 590.0
0.1 Hz
*1
0.0 - 255.0
0.1 V
0.0 - 590.0
0.1 Hz
*1
0.0 - 255.0
0.1 V
Determined by
0.0 - 590.0
o1-04
*1
0.0 - 255.0
0.1 V
*1
0.0 - 255.0
0.1 V
*1
0.0 - 255.0
0.1 V
*1
0.0 - 255.0
0.1 V
0.0 - 400.0
0.1 Hz
0.00 - 10.00
0.01 s
-200 - +200
1%
0.0 - 20.0
0.1 Hz
0.00 - 10.00
0.01 s
Motor 2 Control Method (setting value of E3-01)
V/f
CL-V/f
(0)
(1)
0.0
-
2000
-
200
200
200
200
-
0.20
-
0.200
-
0.02
-
0.050
-
-
50.0
50.0
200.0
200.0
50.0
50.0
2.5
2.5
15.0
15.0
1.3
1.3
9.0
9.0
0.0
0.0
0.0
0.0
0.0
0.0
15.0
15.0
9.0
9.0
3.0
3.0
0.30
0.30
-
-
3.0
3.0
0.30
0.30
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
OLV
CLV
(2)
(3)
1.0
1.0
200
-
20
-
20
-
-
20.00
-
0.500
-
20.00
-
0.500
-
0.004
50.0
50.0
200.0
200.0
50.0
50.0
3.0
-
14.4
-
0.5
0.0
3.0
-
0.0
0.0
0.0
0.0
0.0
0.0
14.4
-
3.0
-
3.0
0.0
0.30
0.00
50
0
3.0
0.0
0.30
0.00

Advertisement