YASKAWA CR700 Technical Manual page 691

Hide thumbs Also See for CR700:
Table of Contents

Advertisement

Note:
Refer to
Setting Procedures for Multi-step Speed Operation on page 622
5: Multi-Step Speed Reference 3
Setting Value
Function
5
Multi-Step Speed Reference
3
Note:
Refer to
Setting Procedures for Multi-step Speed Operation on page 622
6: Jog Reference Selection
Setting Value
Function
6
Jog Reference Selection
7: Accel/Decel Time Selection 1
Setting Value
Function
7
Accel/Decel Time Selection
1
Note:
C1: Accel & Decel Time on page 600
Refer to
8: Baseblock Command (N.O.)
Setting Value
Function
8
Baseblock Command (N.
O.)
The keypad flashes bb [Baseblock]. Acceleration always starts from the zero speed when the Run command is
input. The drive keeps the baseblock state when the Run command is not input.
WARNING! Sudden Movement Hazard. When you use a mechanical holding brake with the drive in a lifting application, you
must close the brake if an input terminal triggers the Baseblock command to stop drive output. If you enter the baseblock
command, the motor will suddenly coast and the load will slip, which can cause serious injury or death.
ON : Baseblock (drive output stop)
OFF : Normal operation
9: Baseblock Command (N.C.)
Setting Value
Function
9
Baseblock Command (N.
C.)
The keypad flashes bb [Baseblock].
WARNING! Sudden Movement Hazard. When you use a mechanical holding brake with the drive in a lifting application, you
must close the brake if an input terminal triggers the Baseblock command to stop drive output. If you enter the baseblock
command, the motor will suddenly coast and the load will slip, which can cause serious injury or death.
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Uses speed references d1-01 to d1-16 to set a multi-step speed reference.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive to use the JOG Frequency Reference (JOG command) set in d1-17. The JOG Frequency command overrides
Frequency References 1 to 8 (d1-01 to d1-08].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive to use Acceleration/Deceleration Time 1 [C1-01, C1-02] or Acceleration/Deceleration Time 2 [C1-03, C1-04].
for more information.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command that stops drive output and coasts the motor to stop when a baseblock command (N.O.) is input.
Figure 11.51 Baseblock Command Time Chart
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command that stops drive output and coasts the motor to stop when baseblock command (N.C.) is input (turned OFF).
11.8 H: Terminal Functions
for more information.
Description
for more information.
Description
Description
Description
Description
11