10.10 H: Terminal Functions
No.
Name
(Hex.)
H3-09
Terminal A2 Signal
Level Select
(0417)
H3-10
Terminal A2 Function
Selection
(0418)
H3-11
Terminal A2 Gain
Setting
(0419)
RUN
H3-12
Terminal A2 Bias
Setting
(041A)
RUN
H3-13
Analog Input FilterTime
Constant
(041B)
H3-14
Analog Input Terminal
Enable Sel
(041C)
H3-16
Terminal A1 Offset
(02F0)
H3-17
Terminal A2 Offset
(02F1)
H3-18
Terminal A3 Offset
(02F2)
H3-40
Mbus Reg 15C1h Input
Function
(0B5C)
H3-41
Mbus Reg 15C2h Input
Function
(0B5F)
H3-42
Mbus Reg 15C3h Input
Function
(0B62)
H3-43
Mbus Reg Inputs
FilterTime Const
(117F)
H3-xx: Multi-Function Analog Input Terminal Settings
Setting Value
Function
0
Frequency Reference
1
Frequency Gain
2
Auxiliary Frequency
Reference 1
3
Auxiliary Frequency
Reference 2
4
Output Voltage Bias
5
Accel/Decel Time Gain
510
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the input signal level for MFAI terminal A2.
0 : 0-10V (Lower Limit at 0)
1 : -10 to +10V (Bipolar Reference)
2 : 4 to 20 mA
3 : 0 to 20 mA
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for MFAI terminal A2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain of the analog signal input to MFAI terminal A2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the bias of the analog signal input to MFAI terminal A2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant for primary delay filters on MFAI terminals.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the enabled terminal or terminals when H1-xx = C [MFDI Function Select =
Analog Terminal Enable Selection] is ON.
1 : Terminal A1 only
2 : Terminal A2 only
3 : Terminals A1 and A2
4 : Terminal A3 only
5 : Terminals A1 and A3
6 : Terminals A2 and A3
7 : Terminals A1, A2, and A3
V/f
CL-V/f
OLV
CLV
AOLV
Sets the offset level for analog signals input to terminal A1. Usually it is not necessary
to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the offset level for analog signals input to terminal A2. Usually it is not necessary
to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the offset level for analog signals input to terminal A3. Usually it is not necessary
to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS AI1 function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS AI2 function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the MEMOBUS AI3 function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant to apply a primary delay filter to the MEMOBUS analog input
register values.
V/f
CL-V/f
OLV
CLV
AOLV
The input value from the MFAI terminal set with this function becomes the master frequency reference.
V/f
CL-V/f
OLV
CLV
AOLV
The drive multiplies the analog frequency reference with the input value from the MFAI set with this function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets Reference 2 through multi-step speed reference to enable the command reference (Auxiliary Frequency
Reference 1) from the analog input terminal set here. This value is a percentage of the maximum output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets Reference 3 through multi-step speed reference to enable the command reference (Auxiliary Frequency
Reference 2) from the analog input terminal set here. This value is a percentage of the maximum output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Set this parameter to input a bias signal and amplify the output voltage.
V/f
CL-V/f
OLV
CLV
AOLV
Enters a signal to adjust the gain used for C1-01 to C1-08 [Acceleration/Deceleration Times 1 to 4] and C1-09
[Fast Stop Time] when the full scale analog signal (10 V or 20 mA) is 100%.
Description
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Default
Ref.
(Range)
2
727
(0 - 3)
0
727
(0 - FF)
100.0%
728
(-999.9 - +999.9%)
0.0%
728
(-999.9 - +999.9%)
0.03 s
728
(0.00 - 2.00 s)
7
728
(1 - 7)
0
729
(-500 - +500)
0
729
(-500 - +500)
0
729
(-500 - +500)
F
729
(4 - 2F)
F
729
(4 - 2F)
F
729
(4 - 2F)
0.00 s
730
(0.00 - 2.00 s)
Ref.
730
730
730
730
730
731