S5: Overload Detection; S6: Overtorque Detection - YASKAWA CR700 Technical Manual

Hide thumbs Also See for CR700:
Table of Contents

Advertisement

S5: Overload Detection

No.
Name
(Hex.)
S5-01
OverL Detect Operation
Select 1
(06B0)
S5-02
OverL Detect Operation
Select 1
(06B1)
S5-03
Overload Detection
Time 1
(06B2)
S5-04
OverL Detect Operation
Select 2
(06B3)
S5-05
Overload Detection
Torque 2
(06B4)
S5-06
Overload Detection
Time 2
(06B5)

S6: Overtorque Detection

No.
Name
(Hex.)
S6-01
OverT Detect Operation
Select 1
(06B6)
S6-02
Overtorque Detection
Level 1
(06B7)
S6-03
Overtorque Detection
Time 1
(06B8)
S6-04
OverT Detect Operation
Select 2
(06B9)
S6-05
Overtorque Detection
Level 2
(06BA)
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets whether to enable or disable overload detection, the detection conditions, and the
drive operation after detection of faults.
0 : Disabled
1 : oL5 @ Speed Agree - Alarm only
2 : oL5 @ RUN - Alarm only
3 : oL5 @ Speed Agree - Alarm only2
4 : oL5 @ RUN - Alarm only2
5 : oL5 @ Speed Agree - Fault
6 : oL5 @ RUN - Fault
V/f
CL-V/f
OLV
CLV
AOLV
Sets the level to trigger an overload.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the overload detection time 1.
V/f
CL-V/f
OLV
CLV
AOLV
Sets whether to enable or disable overload detection, the detection conditions, and the
drive operation after detection of faults.
0 : Disabled
1 : oL5 @ Speed Agree - Alarm only
2 : oL5 @ RUN - Alarm only
3 : oL5 @ Speed Agree - Alarm only2
4 : oL5 @ RUN - Alarm only2
5 : oL3 @ Speed Agree - Fault
6 : oL3 @ RUN - Fault
V/f
CL-V/f
OLV
CLV
AOLV
Sets the level to trigger an overload.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the overload detection time 2.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets whether to enable or disable overtorque detection, the detection conditions, and the
drive operation after detection of faults.
0 : Disabled
1 : oL3 @ Speed Agree - Alarm only
2 : oL3 @ RUN - Alarm only
3 : oL3 @ Speed Agree - Fault
4 : oL3 @ RUN - Fault
5 : oL3 @ Speed Agree - Alarm only2
6 : oL3 @ RUN - Alarm only2
V/f
CL-V/f
OLV
CLV
AOLV
Sets the level to trigger an overtorque.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the overtorque detection time 1.
V/f
CL-V/f
OLV
CLV
AOLV
Sets whether to enable or disable overtorque detection, the detection conditions, and the
drive operation after detection of faults.
0 : Disabled
1 : oL3 @ Speed Agree - Alarm only
2 : oL3 @ RUN - Alarm only
3 : oL3 @ Speed Agree - Fault
4 : oL3 @ RUN - Fault
5 : oL3 @ Speed Agree - Alarm only2
6 : oL3 @ RUN - Alarm only2
V/f
CL-V/f
OLV
CLV
AOLV
Sets the level to trigger an overtorque.
10.14 S: Crane Parameters
Default
Ref.
(Range)
0
213
(0 - 6)
226
150%
213
(0 - 300%)
226
0.1 s
213
(0.0 - 10.0 s)
226
0
213
(0 - 6)
226
150%
213
(0 - 300%)
226
0.1 s
213
(0.0 - 10.0 s)
226
Default
Ref.
(Range)
0
214
(0 - 6)
226
150%
214
(0 - 300%)
226
0.1 s
214
(0.0 - 10.0 s)
226
0
214
(0 - 6)
226
150%
214
(0 - 300%)
226