S2: Run Command Tuning, Maintenance Monitors, Frequency Derating Gain, Rapid; Deceleration - YASKAWA CR700 Technical Manual

Hide thumbs Also See for CR700:
Table of Contents

Advertisement

10.14 S: Crane Parameters
No.
Name
(Hex.)
S1-39
M2 Seq Fault SE2
Detect Time
(06D4)
S1-40
M2 Seq Fault SE3
Detect Time
(06D5)
S1-41
M2 Seq Fault SE4
Detect Time
(06D6)
S1-42
Motor2 Operation in
Reverse
(06D7)
S1-52
Motor3 Brake Release
Freq (FWD)
(1A80)
S1-53
Motor3 Brake Hold Freq
(FWD)
(1A81)
S1-54
Brake Sequence
Selection
(06FD)
S1-55
Motor 2 Brake Sequence
Selection
(06FE)
S1-56
Motor 3 Brake Sequence
Selection
(06FF)
S2: Run Command Tuning, Maintenance Monitors, Frequency Derating Gain,
Rapid Deceleration
No.
Name
(Hex.)
S2-01
Run Cmd Minimum On
Time (FWD)
(0694)
S2-02
Run Cmd Minimum On
Time (REV)
(0695)
S2-03
Run Cmd Delay Timer
(REV/FWD)
(0696)
S2-08
Number of Driving
count selec
(1A82)
S2-09
Motor1 Number of
Driving start
(1A83)
S2-10
Motor2 Number of
Driving start
(1A84)
S2-11
Motor3 Number of
Driving start
(1A85)
S2-12
MentenanceTimer
Output Selection
(1A86)
S2-13
Motor1 Number of
Driving Limit
(1A87)
532
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 2 sequence fault SE2 detection time.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 2 sequence fault SE3 detection time.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 2 sequence fault SE4 detection time.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 2 reverse operation.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 3 brake release frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 3 brake hold frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Enables and disables operation toward a brake sequence.
0 : Disable
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Enables or disables the motor 2 brake sequence
0 : Disable
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Enables or disables the motor 3 brake sequence
0 : Disable
1 : Enabled
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time that the Forward run command is held internally.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time that the Reverse run command is held internally.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time before the Forward run command is accepted after the reverse run stops.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of startup count for motors 1 to 3.
0 : Run Command count
1 : Brake Release Command count
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 1 startup count in increments of 10,000 repetitions. Starts counting from
the set value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 2 startup count in increments of 10,000 repetitions. Starts counting from
the set value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 3 startup count in increments of 10,000 repetitions. Starts counting from
the set value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the method of alarm output.
0 : Disable
1 : Alarm
2 : Fault
V/f
CL-V/f
OLV
CLV
AOLV
Sets the startup count 1 fault/minor fault output level in increments of 10,000
repetitions.
CnT1 [Number of Driving Over] is detected when S2-13 = U4-54 [Num of Driv 1
(High)].
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Default
Ref.
(Range)
1.00 s
216
(0.00 - 2.00 s)
226
0.50 s
216
(0.00 - 2.00 s)
226
0.50 s
216
(0.00 - 2.00 s)
226
0
216
(0, 1)
226
2.0 Hz
216
(0.0 - 20.0 Hz)
226
2.0 Hz
216
(0.0 - 20.0 Hz)
226
1
181
(0, 1)
1
216
(0, 1)
226
1
216
(0, 1)
226
Default
Ref.
(Range)
0.00 s
204
(0.00 - 10.00 s)
226
0.00 s
204
(0.00 - 10.00 s)
226
0.00 s
204
(0.00 - 10.00 s)
226
0
221
(0, 1)
226
0
221
(0 - 1000)
226
0
221
(0 - 1000)
226
0
221
(0 - 1000)
226
0
221
(0 - 2)
226
0
221
(0 - 999)