Model Specifications (400 V Class)

Model
Maximum Applicable Motor Output
*1
(kW)
Rated
AC
Input
Input
*2
Current
DC
(A)
Rated Output Capacity
*3
(kVA)
Rated Output Current
(A)
150% of the rated output current for 60 s
Overload Tolerance
8 kHz without derating the drive capacity.
Output
Carrier Frequency
Derate the drive capacity to use values to 15 kHz maximum.
Three-phase 380 V to 480 V
Maximum Output
Voltage
• AOLV (Advanced Open Loop Vector): 120 Hz
Maximum Output
• CL-V/f (Closed Loop V/f Control), CLV (Closed Loop Vector): 400 Hz
Frequency
• V/f (V/f Control), OLV (Open Loop Vector): 590 Hz
Measures
for
DC reactor
External options
Harmonics
Braking
Braking Transistor
Standard internal characteristics
Device
EMC Filter
Factory option
EMC
Filter
IEC61800-3, C3
• Models 4xxxB: There is a category C3 EMC filter in the drive.
• Three-phase AC power supply 380 V to 480 V at 50/60 Hz
Rated Voltage/Rated
Frequency
• DC power supply 513 V to 679 V
Permitted Voltage
-15% to +10%
Power
Fluctuation
Supply
Permitted Frequency
±5%
Fluctuation
*4
Input Power
(kVA)
*1
The maximum applicable motor output complies with 380 V motor ratings as specified in Annex G of IEC 60947-4-1. The rated
output current of the drive output amps must be equal to or more than the motor rated current.
*2
Assumes the value at the rated output current. The input current rating changes when the power supply transformer, input reactor,
wiring connections, or power supply impedance change.
*3
The rated output capacity is calculated with a rated output voltage of 380 V.
*4
The power supply capacity is calculated with the voltage between lines at 480 V.
Model
Maximum Applicable Motor Output
*1
(kW)
Rated
AC
Input
Input
*2
Current
DC
(A)
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Table 9.3 Rating (400 V Class)
4002
4003
4005
4006
0.55
1.1
1.5
2.2
1.9
3.5
4.7
6.7
2.3
4.3
5.8
8.2
1.2
2.2
3.2
3.6
1.8
3.4
4.8
5.5
Note:
Derating can be necessary for applications that start and stop frequently.
Note:
The maximum output voltage is proportional to the input voltage.
1.5
2.8
3.7
5.3
Table 9.4 Rating (400 V Class)
4045
4060
4075
4091
22
30
37
43.1
58.3
71.5
86.5
53
72
88
106
9.3 Model Specifications (400 V Class)
4007
4009
4015
3
4.0
5.5
8.9
11.7
15.8
11
15
20
4.7
6.1
10
7.2
9.2
14.8
7.1
9.3
13
4112
4150
4180
45
55
75
90
105
142
170
129
174
209
4018
4024
4031
4039
7.5
11
15
18.5
21.2
30.6
41.3
50.5
26
38
51
62
12
16
20
26
18
24
31
39
17
24
33
40
4216
4260
4304
4371
110
132
160
200
207
248
300
373
254
304
367
457
9
431