11.3 b: Application
Note:
Set L2-03 to a high enough value so that oC [Overcurrent] is not triggered when using DC Injection Braking to stop the motor.
3 : Coast to Stop with Timer
The drive shuts off its output when the Stop command is entered (or when the Run command is switched OFF).
The motor coasts to stop. The drive ignores the Run command until the "Run wait time" t has passed.
To start the drive again, re-enter the Run command once the "Run wait time" t has passed.
The active deceleration time and the output frequency when the Stop command is entered determine the length of
"Run wait time" t.
b1-04: Reverse Operation Selection
No.
Name
(Hex.)
b1-04
Reverse Operation
Selection
(0183)
The drive does not accept the Reverse operation command when reverse operation is prohibited.
0 : Reverse Enabled
The drive accepts the Reverse operation command.
1 : Reverse Disabled
The drive disregards the Reverse operation command.
588
Figure 11.13 DC Injection Braking Time and Output Frequency
Figure 11.14 Coast to Stop with Timer
Figure 11.15 Run Wait Time and Output Frequency
V/f
CL-V/f
OLV
CLV
Sets the reverse operation function.
Description
AOLV
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Default
(Range)
0