10.13 O: Keypad-Related Settings; O1: Keypad Display - YASKAWA CR700 Technical Manual

Hide thumbs Also See for CR700:
Table of Contents

Advertisement

10.13 o: Keypad-Related Settings

10.13 o: Keypad-Related Settings

o1: Keypad Display

No.
Name
(Hex.)
o1-01
User Monitor Selection
(0500)
RUN
o1-02
Monitor Selection at
Power-up
(0501)
RUN
o1-03
Frequency Display Unit
Selection
(0502)
o1-04
V/f Pattern Display Unit
(0503)
o1-05
LCD Contrast
Adjustment
(0504)
RUN
o1-10
User Units Maximum
Value
(0520)
o1-11
User Units Decimal
Position
(0521)
o1-20
Sheave Diameter
(0575)
o1-21
Roping Ratio
(0576)
o1-22
Gear Ratio
(0577)
o1-24 to o1-35:
Custom Monitor 1 to 12
(11AD - 11B8)
RUN
o1-36
LCD Backlight
Brightness
(11B9)
RUN
o1-37
LCD Backlight ON/OFF
Selection
(11BA)
RUN
524
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the U monitor for the Drive Mode. This parameter is only available with an LED
keypad.
Note:
You cannot select U2 Monitors [Fault Trace] or U3 Monitors [Fault History].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the monitor item that the keypad screen shows after you energize the drive. Refer
to "U: Monitors" for information about the monitor items that the keypad screen can
show. This parameter is only available with an LED keypad.
1 : Frequency Reference (U1-01)
2 : Direction
3 : Output Frequency (U1-02)
4 : Output Current (U1-03)
5 : User Monitor (o1-01)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the display units for the frequency reference and output frequency.
0 : 0.01 Hz
1 : 0.01% (100% = E1-04)
2 : min
(r/min) units
-1
3 : User Units (o1-10 & o1-11)
4 : 0.01m/min
V/f
CL-V/f
OLV
CLV
AOLV
Sets the setting unit for parameters that set the V/f pattern frequency.
0 : Hz
1 : min
(r/min) units
-1
V/f
CL-V/f
OLV
CLV
AOLV
Sets the contrast of the LCD display on the keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the value that the drive shows as the maximum output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of decimal places for frequency reference and monitor values.
0 : No Decimal Places (XXXXX)
1 : One Decimal Places (XXXX.X)
2 : Two Decimal Places (XXX.XX)
3 : Three Decimal Places (XX.XXX)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the sheave diameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the roping ratio.
1 : 1:1
2 : 1:2
3 : 1:3
4 : 1:4
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gear ratio.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a maximum of 12 monitors as user monitors. This parameter is only available when
using an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the intensity of the LCD keypad backlight.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the automatic shut off function for the LCD backlight.
0 : OFF
1 : ON
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Default
Ref.
(Range)
106
782
(104 - 999)
1
782
(1 - 5)
Determined by A1-02
782
(0 - 4)
Determined by A1-02
783
(0, 1)
5
783
(0 - 10)
Determined by o1-03
784
(1 - 60000)
Determined by o1-03
784
(0 - 3)
400 mm
784
(100 - 2000 mm)
2
784
(1 - 4)
14.00
784
(0.10 - 50.00)
o1-24: 101
784
o1-25: 102
o1-26: 103
o1-27 to o1-35: 0
(0, 101 - 999)
3
785
(1 - 5)
1
785
(0, 1)

Advertisement

Table of Contents
loading