TS- Set Real-Time Clock

Purpose:
Syntax:
Remarks:

U- Print Configuration (General)

Purpose:
Syntax:
ESim for the PC4 and PF8 Printer Programmer's Reference Manual
This command is used to set the time and date in the optional
real-time clock circuit.
TSp
,p
,p
,p
,p
,p
1
2
3
4
5
6
.
TS Command Parameter Descriptions
Parameter
Description
p
Months are entered as 0-12.
1
p
Days are entered as 01-31.
2
p
Years are entered as the last two digits. For
3
example 2004 is entered as 04.
p
Hours entered in 24 hour format (00-23).
4
p
Minutes are entered as 00-59.
5
p
Seconds are entered as 00-59.
6
This command works only if the printer is fitted with an optional
real-time clock circuit (RTC).
Example:
This example sets the date to JAN 15,2004 and the time to
12:45:23 p.m.
TS01,15,04,12,45,23
This command is used to print the current printer configuration
on a label without having to enter Dump mode.
U
Example:
This example shows a typical label printed when using the U
command with the following setup:
• Memory cartridge loaded
• Media with black marks
• Two forms, two graphics, and five soft fonts loaded
• Short labels