Intermec EasyCoder PC4 Programmer's Reference Manual page 75

Esim
Hide thumbs Also See for EasyCoder PC4:
Table of Contents

Advertisement

Chapter 7 — Commands
Remarks:
60
This command is used in forms that require sequential
numbering. When initializing counters, they must be defined in
order (for example C0, C1, C2, etc.) after possible variables.
To print the contents of the counter, the counter number
(C0- C9) is entered in the "DATA" field of A (Print Text) or B
(Print Bar Code) commands.
Prompts only display if a UI command has been issued after last
power-up. The Keyboard display unit sends the UI command
automatically.
The field justification parameter (p
is printed. When p
3
left, right or center justified in an area with a width defined by p
(number of digits). If no justification is selected
(p
= N), the field is truncated from the right side so as to not
3
exceed the set maximum field length, which may be useful when
using a counter as input data to a bar code.
If the start value entered, when the form is retrieved for printing,
is started by one or several zeros (0), the entire area specified by
p
(number of digits) is padded with leading zeros and p
2
justification) has no effect.
Note: If a single counter is incremented several times on the same
form, then the step value p
the counter is used in the form or equivalent to what the step
values for the single counter add up to in this form. A Cn±x
command must also be used when designing the actual form. See
the A and B commands.
ESim for the PC4 and PF8 Printer Programmer's Reference Manual
) affects the way the counter
3
= L, R, or C, the counter value is printed
must be set to the number of times
4
2
(field
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pf8

Table of Contents