Ds3 Cleanup Procedures - Alcatel-Lucent 1665 Installation Manual

Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Installation tests

DS3 cleanup procedures

............................................................................................................................................................................................................................................................
Delete the existing DS3 cross-connections
Before moving on to the next port to test, it is necessary to remove the cross-connection.
........................................................................................................................................................................................................................
Select Configuration -> Cross-Connections...
1
........................................................................................................................................................................................................................
Use the Cross-Connection Wizard to Delete leg(s) of an existing cross-connection
2
associated with CP main-1, Port 1.
Result:
of the PRBS signal.
........................................................................................................................................................................................................................
Remove the test set connections from the DSX-3.
3
........................................................................................................................................................................................................................
Select Configuration -> Update System... -> Update All.
4
Result:
from the DSX-3.
........................................................................................................................................................................................................................
Repeat the
5
the
DS3 non-terminating transmission (optical main OLIU) (p. 4-26)
Delete the existing DS3 cross-connections (p. 4-32)
remaining DS3 tributaries of the Function Unit, substituting the following address
information within the Cross-Connection Wizard. This is necessary in order to ensure that
the cabling of each port address is correct.
The table below lists the tributaries and cross-connections for all DS3s associated with a
function group.
When testing cabling for a Function Unit slot other than a, replace the
addresses with the letter (
............................................................................................................................................................................................................................................................
4 - 3 2
The DS3 test set should indicate a blue (AIS) signal is being received in place
This command will remove alarms generated by removing the test signals
DS3 terminating equipment loopback testing (optical main OLIUs) (p. 4-23)
,
, or
b
c
procedure to test each of the
) corresponding to the Function Unit slot under test.
d
DS3 cleanup procedures
or
procedure and the
in each of the
a
365-372-304R7.1
Issue 1, November 2007