Installation tests
OC-48 (low-speed) testing
LED test
Additional optical tests (optional)
Tools, test equipment and accessories
Listed below are the required tools, test equipment and accessories. For complete listing
see Part I or Part II.
Quantity
1
1
1
1
2 or 3
............................................................................................................................................................................................................................................................
4 - 2
Description
Screwdriver(s)
ESD Wrist Strap
DS1 Error Rate Test Set
DS3 Error Rate Test Set
SONET Optical Test Set
LC-type Optical Fiber Jumper
(108918269)
Comments
A screwdriver(s) with the appropriate head(s) is
(are) required for securing the mounting screws,
repositioning the mounting brackets, installing
the interfacing cables, and for setting the circuit
breakers to the OFF position.
A wrist strap must be worn when handling
circuit packs. Use the electrostatic discharge
(ESD) jack provided on the shelf.
A DS1 error rate test set is required for testing
of DS1 cabling. A T-BERD 2209 or equivalent
is recommended.
A DS3 error rate test set is required for testing
of DS3/EC1 and TMUX cabling. A T-BERD
2209 or equivalent is recommended.
An OC-3, OC-12 or OC-48 test set as required
for testing of optical circuit packs. An Agilent
OmniBER 718 or equivalent is recommended.
Two optical fiber jumpers with LC-type
connectors are required to optically loop the
1665 DMX
shelf for test purposes.
In addition, for shelves containing optical
circuit packs in any of the Function Unit slots, a
single optical fiber jumper is required for testing
of the individual ports.