System cabling
Figure 4-43 Cable design (LAN cable - GE)
Table 4-15
Point on Connector
1
2
3
4
5
6
7
8
Cable data
A standard LAN cable (CAT5) can be used (100 Ω symmetrical).
Cable connection
Please connect the LAN cables as shown in the figure below.
....................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Pin assignment (LAN cable - GE)
Signal Name
BI_DA +
BI_DA -
BI_DB +
BI_DC +
BI_DC -
BI_DB -
BI_DD +
BI_DD -
Alcatel-Lucent - Proprietary
See notice on first page
LAN interfaces (X4IP, X8PL and X5IP card)
MDI Connector
Signal Name
BI_DB +
BI_DB -
BI_DA +
BI_DD +
BI_DD -
BI_DA -
BI_DC +
BI_DC -
Description
Bidirectional data,
poistive
Bidirectional data,
negative
Bidirectional data,
positive
Bidirectional data,
positive
Bidirectional data,
negative
Bidirectional data,
negative
Bidirectional data,
positive
Bidirectional data,
negative