Acceptability Criteria For Fiber Cleaning - Alcatel-Lucent 1665 Installation Manual

Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Fiber cleaning
Figure B-3
No LOOSE
contamination or
particulate fibers
in viewing area. If
not removable in 3
cleaning attempts,
it is defined as
fixed particulate.
Fixed
(<8.0µm in size)
allowed in this area.
........................................................................................................................................................................................................................
After the connector has been verified to be cleaned, it should be immediately inserted into
3
the adapter buildout of the optical component. This will assure maximum cleanliness and
effectiveness of the connector.
........................................................................................................................................................................................................................
If the cleaned connector cannot be immediately connected to a corresponding adapter, the
4
connector ferrule must be protected with a connector dust cap. Before placing the cap on
the ferrule, make sure the cap is clean. This can be accomplished by inserting a CLETOP
stick cleaner (swab) of the same inside diameter as the cap (either 2.5 or 1.25 mm) and
rotate the stick 360 degrees three (3) times. Following this procedure, carefully place the
cap over the ferrule. When the cleaned connector is ready for assembly, it should be re-
inspected for cleanliness prior to connection.
E
O
N D
........................................................................................................................................................
Fiber adapters or circuit pack connectors
During testing and/or trouble shooting activities it may be necessary to clean the optical
buildout adapter or the circuit pack connector. The following procedure is recommended.
............................................................................................................................................................................................................................................................
B - 1 0

Acceptability Criteria for Fiber Cleaning

Monitor
Viewing
Area
particles
S
F
T E P S
CAUTION
Do not attempt to clean ports equipped with yellow Light guide BuildOut (LBO)
attenuators. Attenuators contain a thin glass lens that is extremely fragile. The
LBO will be damaged if cleaned using this method.
Cleaning/inspecting optical connectors
core
fiber
Restricted Area
1/2 SM Core + 1/2 Fiber
Diameters - 66 µm dia.
No Loose or No Fixed
Contamination
m
66u
365-372-304R7.1
Issue 1, November 2007