Ring setup and testing: integration procedures
........................................................................................................................................................................................................................
Select the proper LBO based on the value required and the comcode as listed below.
13
........................................................................................................................................................................................................................
Clean LC LBOs and install LBO assemblies in the OLIU IN connector.
14
........................................................................................................................................................................................................................
At the far end, connect the input optical fiber to the proper OLIU IN connector.
15
Requirement: The FAULT LED on the OLIU extinguishes.
........................................................................................................................................................................................................................
At the near end, connect the input optical fiber to the proper OLIU IN connector.
16
Requirement: The FAULT LED on the OLIU extinguishes.
........................................................................................................................................................................................................................
Disconnect the fiber cable from the OUT connector on the OLIU at one end of the span.
17
At the other end, verify that the associated FAULT LED is flashing, indicating a loss of
signal. Reconnect the fiber and repeat the process for the other direction of transmission.
........................................................................................................................................................................................................................
Enable communications with the adjacent 1665 DMX nodes. Configuration -> DCC
18
Terminations...
........................................................................................................................................................................................................................
Select Port AID: dcc-m1-1, OSI Over DCC: enabled, LAPD Role: user-side.
19
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 1, November 2007
SFP/XFP
Circuit Pack
optics
OC192LR2-C1
LNW59, LNW502
Code
ABLCS-05.0
ABLCS-10.0
ABLCS-15.0
ABLCS-20.0
Comcode
Loss (dB)
108279381
5
108279431
10
108279480
15
108279530
20
Fiber installation
Received
LBO
Power (dBM)
(dB)
+4.0 to 0.0
15dB
0.0 to -7.0
10
-7.0 to -24.0
0
6 - 9