Miscellaneous (Environmental) Discrete Telemetry Connections - Alcatel-Lucent 1665 Installation Manual

Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Equipment and cable installation for 1665 Data Multiplexer
(1665 DMX)
Table 1-23
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 1, November 2007

Miscellaneous (environmental) discrete telemetry connections

Conn.
Pin#
J11
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Miscellaneous (environmental) discrete telemetry cable
Color
Designation
BL-W
TLMI1
W-BL
TLMI2
O-W
TLMI3
W-O
TLMI4
G-W
TLMI5
W-G
TLMI6
BR-W
TLMI7
W-BR
TLMI8
S-W
TLMI9
W-S
TLMI10
BL-R
TLMI11
R-BL
TLMI12
O-R
TLMI13
R-O
TLMI14
G-R
TLMI15
R-G
TLMI16
BR-R
TLMI17
R-BR
TLMI18
S-R
TLMI19
R-S
TLMIC48VTRN
BL-BK/
TLMO1
BK-BL
TLMO2
O-BK
TLMO3
BK-O
TLMO4
G-BK
TLMOC
installation
Name
Env. Input - #1
Env. Input - #2
Env. Input - #3
Env. Input - #4
Env. Input - #5
Env. Input - #6
Env. Input - #7
Env. Input - #8
Env. Input - #9
Env. Input - #10
Env. Input - #11
Env. Input - #12
Env. Input - #13
Env. Input - #14
Env. Input - #15
Env. Input - #16
Env. Input - #17
Env. Input - #18
Env. Input - #19
Input Common
Env. Output - #1
Env. Output - #2
Env. Output - #3
Env. Output - #4
Output Common