Alcatel-Lucent 1665 Installation Manual page 256

Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Operational tests
This command creates a cross-connection to map 28 DS1s of a DS1circuit pack or the first
DS3 of a DS3/EC1 or TMUX circuit pack in a Function Unit slot(s) to the first STS-1 of
the Main OLIUs.
........................................................................................................................................................................................................................
6
Select Configuration -> Alarms -> Alarm Configuration.
........................................................................................................................................................................................................................
Choose Power Alarm Level: Major.
7
........................................................................................................................................................................................................................
Click OK.
8
........................................................................................................................................................................................................................
Unseat one of the LNW6/LNW7/LNW8, LNW16/LNW19/LNW19B or LNW18 circuit
9
packs from the function group being used.
Requirement: Activated office alarms: MN visual, MN audible.
Important!
default time is 2 seconds.
........................................................................................................................................................................................................................
Press the ACO pushbutton on the SYSCTL.
10
Requirement: Activated office alarm: MN visual.
The MN audible alarm clears.
........................................................................................................................................................................................................................
Using a small flat bladed screwdriver, set one of the circuit breakers to OFF.
11
Requirement: Activated office alarms: MN visual, MN audible.
........................................................................................................................................................................................................................
Press the ACO pushbutton on the SYSCTL.
12
Requirement: Activated office alarm: MJ visual.
The MJ audible alarm should clear.
........................................................................................................................................................................................................................
13
Unseat the second circuit pack from the same function group pair as the circuit pack
removed in
Result:
............................................................................................................................................................................................................................................................
5 - 6
Alarms will not be activated until the alarm delay time has passed. The
Step
9.
Activated office alarms: CR visual, CR audible.
Office alarm test
365-372-304R7.1
Issue 1, November 2007