d. If you are installing the server into a space with fewer than seven rack units,
you do not need to locate mounting holes or install mounting screws. You are
ready to install the server into the rack. See
Rack" on page

Install the Mounting Screws

G
Install one 10-32 x 1/2 screw on the left and one 10-32 x 1/2 screw on the right
vertical mounting rails.
Use the holes you marked in the previous procedure. Do not fully tighten the screws
until after you install the server. Leave a 0.25-inch (0.64-cm) gap between the head of
each screw and the mounting rail.
26
Sun Fire V490 Server Setup and Rackmounting Guide • August 2004
29.
10-32 x 1/2
10-32 x 1/2
"Install the Server Into a Populated
0.25"