3. With the help of an assistant, position the slide assembly on the right mounting
rail as viewed from the front.
The front (short) mounting bracket should be at the front of the rack.
a. Use the holes you marked in Step 1.
b. Use the same slide assembly you adjusted in Step 2.
c. Make sure that the slide assembly is level front-to-back.
4. Using the appropriate screws for the rack, attach the front mounting bracket to the
front rail of the rack and attach the back (long) mounting bracket of the same
slide assembly to the back rail of the rack.
a. Count the rack rail holes to ensure that you are matching the holes used on the
front rail.
b. Use the appropriate screws for your type of rack:
Racks with mounting holes sized for U.S. dimensions require 10-32 screws.
I
Racks with mounting holes sized for metric dimensions require M6 screws.
I
Partially tighten the front bracket screws and the back bracket screws.
Note – Do not fully tighten the screws that attach the brackets to the vertical
mounting rails until after you use the slide assembly spacer to make sure that the
rails are evenly spaced and aligned.
Chapter 1 Installing a Sun Fire V490 Server Into a 4-Post Cabinet
13