Install the Server Into the Cabinet

Caution – Before you install or remove the server from the cabinet, ensure that the
!
cabinet is stabilized so that it cannot move or tip forward. See the cabinet
documentation for information about stabilizing the cabinet.
Caution – The server is heavy. Two persons are required to install or remove the
!
server into the rack.
Note – Make sure that each slide assembly is fully retracted into the cabinet and
check that the ball-bearing runner on each slide assembly is all the way forward.
1. Lift the server (one person on each side of the server) and approach the cabinet
with the back of the server facing the front of the cabinet.
2. Align the rounded ends of the inner glides on the server with the slide assemblies
in the cabinet.
Note – Make sure that the inner glides attached to the server are inserted within the
ball-bearing runners, and the server is level when inserting it into the ball bearing
runners.
Chapter 1 Installing a Sun Fire V490 Server Into a 4-Post Cabinet