Install The Cable Management Arm; Install The Cable Management Arm - Sun Microsystems Fire V490 Setup And Rackmounting Manual

Table of Contents

Advertisement

Install the Cable Management Arm

This procedure describes how to attach the cable management arm to a Sun Fire
V490 server that is already installed into a cabinet. For instructions on installing the
server into a cabinet, see Chapter 1.
1. Remove the four screws that secure the system to the left and right vertical rails at
the front of the cabinet.
2. Slide the chassis smoothly out of the cabinet about 3 inches (76.2 mm).
Sliding the server out of the cabinet provides easy access to the areas where you will
attach the cable management arm.
3. Attach a hinged bracket to the posts on the inner glide, as shown in the next
figure.
a. Locate the two horizontal posts on the inner glide on the right side of the
chassis as viewed from the rear.
b. Remove the protective covers from the posts.
Chapter 3 Setup Procedures
33

Advertisement

Table of Contents
loading