6. Attach the other end of the cable management arm to the hinged bracket on the
inner glide on the right side of the chassis as viewed from the rear.
a. Locate the hinged bracket on the end of the inner glide.
b. Slide the hinge on the right side of the cable management arm into the hinge
on the hinged bracket attached to the inner glide until the openings in both
hinges are aligned.
c. Insert the speed pin through the aligned openings of the hinges on the bracket
and the cable management arm and push the speed pin down firmly.
7. Connect the power cords and cables to the server ports. See
and Cables" on page
Note – Do not secure the server to the front mounting rails until after you route the
cables onto the cable management arm. It is easier to route the cables onto the cable
management arm when the server is retracted from the rack.
40.
Speed
pin
"Connect the Cords
Chapter 3 Setup Procedures
39