Install the Server Into the Rack

Caution – Before you install or remove the server from the rack, ensure that the
rack is stabilized so that it cannot move or tip forward. See the rack documentation
for information about stabilizing the rack.
Caution – The server is heavy. Two persons are required to move the server.
1. Lift the server (one person on each side of the server) and approach the rack with
the back of the server facing the front of the rack.
2. Lift the server up and over the mounting screw on each vertical mounting rail so
that the large hole clears the head of the screw.
Slide the server down so that the server rests on the mounting screws.
3. Use six 10-32 screws, two screws and the mounting screw on each side, to secure
the server to the vertical mounting rails.
Chapter 2 Installing a Sun Fire V490 Server Into a 2-Post Rack
27