3.2.1.12

DIESEL REGENERATION PAGE

On the DIESEL REGENERATION page it is possible to verify if the regeneration of the SCR system is not
necessary, necessary or urgently required. Different screens appear depending on the situation, as follows:
in this case regeneration of the SCR system is not required. No LED on.
in this case regeneration of the SCR system is required. This screen appears automatically on the display
even without consulting the "DIESEL REGENERATION" page. The Regeneration required L25 LED lights up on
the display.
The operator may momentarily decide not to carry out regeneration by pressing any button at the bottom
of the display. It is advisable to carry out regeneration as soon as possible to avoid that the motor goes into
"protection status" with limitation of the available power.