Snorkel International, LLC
2009 Roseport Road
www.snorkellifts.com
SCR main relay (secondary side): open load
SCR heater relay urea pressure line; open load
SCR main relay; short circuit
SCR main relay; short circuit
SCR heater relay urea supply line; open load
SCR heater relay urea supply module; open load
SCR Tank heating valve; open load
SCR system heater diagnostic reports error; shut off SCR-system
SCR heater relay urea return line; open load
SCR heater urea return line; short circuit to battery
SCR heater urea return line; short circuit to ground
SCR heater relay urea pressure line; open load
SCR heater urea pressure line; short circuit to battery
SCR heater urea pressure line; short circuit to ground
SCR main relay (primary side); open load
SCR main relay (primary side); powerstage over temperature
SCR main relay (primary side); short circuit to battery
SCR main relay (primary side); short circuit to ground
SCR heater relay urea supply line; open load
SCR-heater urea supply line; short circuit to battery
SCR-heater urea supply line; short circuit to ground
SCR heater relay urea supply module; open load
SCR heater urea supply module; short circuit to battery
SCR heater urea supply module; short circuit to ground
SCR Tank heating valve; open load
SCR-heater relay urea tank powerstage output; over temperature
SCR Tank heating valve; short circuit to battery
SCR Tank heating valve; short circuit to ground
Urea pump motor; open load
Urea pump motor; short circuit to battery
Urea pump motor; short circuit to ground
Urea pump pressure; out of range
Urea pump pressure; out of range
Urea pump pressure; out of range
Urea pump pressure; out of range
Sensor error urea pump pressure; signal range check high
Sensor error urea pump pressure; signal range check low
SCR reversing valve; open load
SCR reversing valve; over temperature
SCR reversing valve; short circuit to battery
SCR reversing valve; short circuit to ground
Sensor error urea tank temperature; short circuit to battery
Sensor error urea tank temperature; short circuit to ground
Water in fuel level prefilter; maximum value exceeded
Zerofuel calibration injector 1 (in firing order); maximum value exceeded
Zerofuel calibration injector 2 (in firing order); maximum value exceeded
Zerofuel calibration injector 3 (in firing order); maximum value exceeded
Zerofuel calibration injector 4 (in firing order); maximum value exceeded
165
Elwood, KS 66024
Model: Snorkel SR9244 SR1054
Part Number: 159-0037-000