3.10

REVERSING FAN FUNCTION (OPTIONAL)

The "Reversing fan" is a function for keeping the radiator surface clean and efficient. The function takes
place through reversal of the direction of the cooling fan blades and ensuing reversal of the cooling flow.
The "Reversing fan" can be started automatically (approximately every 30 minutes of work) or manually by
means of button 12 on the right side of the second dashboard.
It is started after the following screen is displayed and the acoustic signal goes off: it is activated within 10
seconds; press the OK button on the display to stop it.
During activation, engine speed has to be less than 1800 rpm, otherwise the following screen will appear: