Sensor error pressure sensor downstream turbine; signal range check high
Urea tank level; warning threshold exceeded
Sensor error urea tank temperature; short circuit to battery
Sensor error urea tank temperature; short circuit to ground
Nox sensor upstream of SCR Catalysator; low signal not plausible
Nox Sensor downstream of SCR Catalysator; plausibility error "stuck in range"
Sensor SCR catalyst upstream temperature too high; plausibility error
Sensor SCR catalyst upstream temperature too low; plausibility error
Exhaust gas temperature particulate filter downstream; out of range, system
Exhaust gas temperature particulate filter downstream; out of range, system
Exhaust gas temperature particulate filter downstream; out of range, system
Exhaust gas temperature particulate filter downstream; out of range, system
Exhaust gas temperature particulate filter downstream; out of range, system
Exhaust gas temperature particulate filter downstream; out of range, system
Sensor error particle filter downstream temperature; signal range check low
Physical range check high for differential pressure (DPF); shut off regeneration
Physical range check low for differential pressure (DPF); shut off regeneration
Sensor differential pressure (DPF); plausibility error
Sensor differential pressure (DPF); plausibility error
Sensor error differential pressure (DPF); signal range check high
Sensor error differential pressure (DPF); signal range check low
Urea dosing valve; short circuit to battery
Urea dosing valve; short circuit to battery
Urea dosing valve; short circuit to ground
Urea dosing valve; short circuit to ground
AdBlue dosing valve blocked (SCR)
Sensor error urea tank level; signal range check high
Sensor error urea tank level; signal range check low
DPF differential pressure sensor and a further sensor or actuator CRT system
SCR system heater diagnostic reports error; shut off SCR-system
Urea pump pressure; out of range
Urea pump pressure; out of range
Urea pump pressure; out of range
Urea pump pressure; out of range
Sensor error urea pump pressure; signal range check high
Sensor error urea pump pressure; signal range check low
SCR-heater urea supply line; short circuit to battery
SCR-heater urea supply line; short circuit to ground
SCR heater relay urea supply line; open load
SCR heater relay urea supply line; open load
SCR heater urea pressure line; short circuit to battery
Snorkel International, LLC
2009 Roseport Road
Elwood, KS 66024
www.snorkellifts.com
reaction initiated
reaction initiated
reaction initiated
reaction initiated
reaction initiated
reaction initiated
defective