ENGINE ERRORS

The list of main engine errors that can be encountered is below (code - description).
If the engine error screen appears (see chapter 3.1.2.11), contact Snorkel service.
FMI
SPN
Blinkcode
523912
2
523912
0
523912
1
off regeneration. When burner injector is actuated, the measured pressure does not
523912
3
523912
4
102
2
102
2
523929
0
523930
0
523931
0
523932
0
523933
0
523934
0
523929
1
523930
1
523931
1
523932
1
523933
1
523934
1
523938
9
523939
9
Burner dosing valve (DV2) downstream pressure sensor; plausibility error
Physical range check high for burner dosing valve (DV2) downstream pressure; shut
Physical range check low for burner dosing valve (DV2) downstream pressure; shut
rise above ca. 1250mbar abs (expected: ca. 2400mbar).
Sensor error burner dosing valve (DV2) downstream pressure sensor; signal range
Sensor error burner dosing valve (DV2) downstream pressure sensor; signal range
Charged air pressure; system reaction initiated
Charged air pressure; system reaction initiated
Fuel Balance Control integrator injector 1 (in firing order); maximum value
Fuel Balance Control integrator injector 2 (in firing order); maximum value
Fuel Balance Control integrator injector 3 (in firing order); maximum value
Fuel Balance Control integrator injector 4 (in firing order); maximum value
Fuel Balance Control integrator injector 5 (in firing order); maximum value
Fuel Balance Control integrator injector 6 (in firing order); maximum value
Fuel Balance Control integrator injector 1 (in firing order); minimum value exceeded
Fuel Balance Control integrator injector 2 (in firing order); minimum value exceeded
Fuel Balance Control integrator injector 3 (in firing order); minimum value exceeded
Fuel Balance Control integrator injector 4 (in firing order); minimum value exceeded
Fuel Balance Control integrator injector 5 (in firing order); minimum value exceeded
Fuel Balance Control integrator injector 6 (in firing order); minimum value exceeded
Timeout Error (BAM to packet) for CAN-Receive-Frame AT1IGCVol1 information;
factors & Sensorcalibration for NOX Sensor (SCR-system upstream cat; DPF- system
Timeout Error (BAM to BAM) for CAN-Receive-Frame AT1IGCVol1 information;
factors & Sensorcalibration for NOX Sensor (SCR-system upstream cat; DPF- system
Snorkel International, LLC
2009 Roseport Road
Elwood, KS 66024
www.snorkellifts.com
Error Identification
off regeneration
check high
check low
exceeded
exceeded
exceeded
exceeded
exceeded
exceeded
downstream cat)
downstream cat)