Table 39. IMM error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)", that step must be performed only by a trained
technician.
806f0021-2582ffff
PCI fault has been
detected for One of
PCI Error.
806f0021-2582ffff
PCI fault has been
detected for All PCI
Error.
Error
A PCI fault has
been detected.
Error
A PCI fault has
been detected.
Appendix C. Integrated management module II (IMM2) error messages
1. Check the PCI LED. See more
information about the PCI LED in
Light path diagnostics.
2. Reseat the affected adapters and
riser cards.
3. Update the server firmware (UEFI
and IMM) and adapter firmware.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
4. Remove both adapters.
5. Replace the riser cards.
6. (Trained technicians only) Replace
the system board (see Removing the
system board and Installing the
system board).
1. Check the PCI LED. See more
information about the PCI LED in
Light path diagnostics.
2. Reseat the affected adapters and
riser cards.
3. Update the server firmware (UEFI
and IMM) and adapter firmware.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code is
supported for the cluster solution
before you update the code.
4. Replace the adapters.
5. Replace the riser cards.
6. (Trained technicians only) Replace
the system board (see Removing the
system board and Installing the
system board).