Table 39. IMM error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)", that step must be performed only by a trained
technician.
80010701-1401ffff
Sensor CPU n VR
80010701-1402ffff
Temp going high
(upper non-critical)
has asserted. (n =
microprocessor
number)
80010901-1401ffff
Sensor CPU n VR
80010901-1402ffff
Temp going high
(upper critical) has
asserted. (n =
microprocessor
number)
80010b01-1401ffff
Sensor CPU n VR
80010b01-1402ffff
Temp going high
(upper
non-recoverable) has
asserted. (n =
microprocessor
number)
80010701-1403ffff
Sensor DIMM AB VR
Temp going high
(upper non-critical)
has asserted.
80010901-1403ffff
Sensor DIMM AB VR
Temp going high
(upper critical) has
asserted.
80010b01-1403ffff
Sensor DIMM AB VR
Temp going high
(upper
non-recoverable) has
asserted.
80010701-1404ffff
Sensor DIMM CD VR
Temp going high
(upper non-critical)
has asserted.
80010901-1404ffff
Sensor DIMM CD VR
Temp going high
(upper critical) has
asserted.
400
System x3500 M4 Type 7383: Installation and Service Guide
Warning An upper
non-critical sensor
going high has
asserted.
Error
An upper critical
sensor going high
has asserted.
Error
An upper
non-recoverable
sensor going high
has asserted.
Warning An upper
non-critical sensor
going high has
asserted.
Error
An upper critical
sensor going high
has asserted.
Error
An upper
non-recoverable
sensor going high
has asserted.
Warning An upper
non-critical sensor
going high has
asserted.
Error
An upper critical
sensor going high
has asserted.
1. Reduce the ambient temperature.
2. Check the server airflow. Make sure
that nothing is blocking the air
from coming into or preventing the
air from exiting the server.
1. Reduce the ambient temperature.
2. Check the server airflow. Make sure
that nothing is blocking the air
from coming into or preventing the
air from exiting the server.
Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air from
exiting the server.
1. Reduce the ambient temperature.
2. Check the server airflow. Make sure
that nothing is blocking the air
from coming into or preventing the
air from exiting the server.
1. Reduce the ambient temperature.
2. Check the server airflow. Make sure
that nothing is blocking the air
from coming into or preventing the
air from exiting the server.
Check the server airflow. Make sure
that nothing is blocking the air from
coming into or preventing the air from
exiting the server.
1. Reduce the ambient temperature.
2. Check the server airflow. Make sure
that nothing is blocking the air
from coming into or preventing the
air from exiting the server.
1. Reduce the ambient temperature.
2. Check the server airflow. Make sure
that nothing is blocking the air
from coming into or preventing the
air from exiting the server.