Table 37. UEFI/POST diagnostic codes (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)", that step must be performed only by a trained
technician.
v Go to the IBM support website at http://www.ibm.com/supportportal to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Diagnostic
code
Message
I.18005
[I.18005] A
discrepancy has
been detected in the
number of cores
reported by one or
more processor
packages within the
system.
I.18006
[I.18006] A
mismatch between
the maximum
allowed QPI link
speed has been
detected for one or
more processor
packages.
I.18007
[I.18007] A power
segment mismatch
has been detected
for one or more
processor packages.
I.18008
[I.18008] Currently,
there is no
additional
information for this
event.
344
System x3500 M4 Type 7383: Installation and Service Guide
Description
Action
Processors have
1. Make sure that the microprocessor is on the ServerProven
mismatched
website at http://www.ibm.com/systems/info/x86servers/
number of
serverproven/compat/us.
cores.
2. Check the IBM support website for a firmware update and
update the server firmware to the latest level (see Updating
the firmware).
3. (Trained technician only) Remove and replace the affected
microprocessor (error LED is lit) with a supported type (see
Removing a microprocessor and heat sink and Installing a
microprocessor and heat sink).
Processors have
1. Make sure that the microprocessor is on the ServerProven
mismatched
website at http://www.ibm.com/systems/info/x86servers/
QPI Speed.
serverproven/compat/us.
2. Check the IBM support website for a firmware update and
update the server firmware to the latest level (see Updating
the firmware).
3. (Trained technician only) Remove and replace the affected
microprocessor (error LED is lit) with a supported type (see
Removing a microprocessor and heat sink and Installing a
microprocessor and heat sink).
Processors have
1. Make sure that the microprocessor is on the ServerProven
mismatched
website at http://www.ibm.com/systems/info/x86servers/
Power
serverproven/compat/us.
Segments.
2. Ensure that all microprocessors have matching power
requirements (such as 65, 95, or 130 Watts).
3. Check the IBM support website for a firmware update and
update the server firmware to the latest level (see Updating
the firmware).
4. (Trained technician only) Remove and replace the affected
microprocessor (error LED is lit) with a supported type (see
Removing a microprocessor and heat sink and Installing a
microprocessor and heat sink).
Processors have
1. Verify that matching DIMMs are installed in the correct
mismatched
population sequence for the server (see DIMM installation
Internal DDR3
sequence). Correct any configuration issues found (see
Frequency.
Removing a memory module and Memory module
installation).
2. (Trained technician only) Remove and replace the affected
microprocessor (error LED is lit) with a supported type (see
Removing a microprocessor and heat sink and Installing a
microprocessor and heat sink). Inspect microprocessor
socket and replace the system board first (see Removing the
system board and Installing the system board) if socket is
damaged.