IBM 7383 Installation And Service Manual page 443

Table of Contents

Advertisement

Table 39. IMM error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)", that step must be performed only by a trained
technician.
806f0a0c-2001ffff
An
806f0a0c-2002ffff
Over-Temperature
806f0a0c-2003ffff
condition has been
806f0a0c-2004ffff
detected on the
806f0a0c-2005ffff
DIMM n Status. (n =
806f0a0c-2006ffff
DIMM number)
806f0a0c-2007ffff
806f0a0c-2008ffff
806f0a0c-2009ffff
806f0a0c-200affff
806f0a0c-200bffff
806f0a0c-200cffff
806f0a0c-200dffff
806f0a0c-200effff
806f0a0c-200fffff
806f0a0c-2010ffff
806f0a0c-2011ffff
806f0a0c-2012ffff
806f0a0c-2013ffff
806f0a0c-2014ffff
806f0a0c-2015ffff
806f0a0c-2016ffff
806f0a0c-2017ffff
806f0a0c-2018ffff
800b010c-2581ffff
Backup Memory
redundancy lost has
asserted.
800b030c-2581ffff
Backup Memory
sufficient resources
from redundancy
degraded has
asserted.
800b050c-2581ffff
Backup Memory
insufficient resources
has asserted.
Storage messages
Error
An
over-temperature
condition has
occurred for DIMM
n. (n = DIMM
number)
Error
Redundancy has
been lost.
Warning There is no
redundancy. The
state has been
transitioned from
redundancy to
sufficient resources.
Error
There is no
redundancy and
insufficient to
continue operation.
Appendix C. Integrated management module II (IMM2) error messages
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow, that the
air baffles are in place and correctly
installed, and that the server cover
is installed and completely closed.
2. Make sure that ambient
temperature is within the
specifications.
3. If a fan has failed, complete the
action for a fan failure.
4. Replace DIMM n.
(n = DIMM number)
1. Check the system-event log for
DIMM failure events (uncorrectable
or PFA) and correct the failures.
2. Re-enable mirrored mode in the
Setup utility.
1. Check the system-event log for
DIMM failure events (uncorrectable
or PFA) and correct the failures.
2. Re-enable mirrored mode in the
Setup utility.
1. Check the system-event log for
DIMM failure events (uncorrectable
or PFA) and correct the failures.
2. Re-enable mirrored mode in the
Setup utility.
425