Table 38. DSA messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by "(Trained technician only)", that step must be performed only by a trained
technician.
v Go to the IBM support website at http://www.ibm.com/supportportal to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Message
number
Component Test
166-813-xxx
IMM
166-814-xxx
IMM
State
Description
2
IMM I
C Test Aborted IMM I
aborted: cannot
return the number
of requested data
bytes.
2
IMM I
C Test Aborted IMM I
aborted: requested
sensor, data, or
record is not
present.
Action
2
C test
1. Turn off the system and disconnect it
from the power source. You must
disconnect the system from ac power
to reset the IMM.
2. After 45 seconds, reconnect the
system to the power source and turn
on the system.
3. Run the test again.
4. Make sure that the DSA code is at
the latest level.
5. Make sure that the IMM firmware is
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component.
6. Run the test again.
7. If the failure remains, go to the IBM
website for more troubleshooting
information.
2
C test
1. Turn off the system and disconnect it
from the power source. You must
disconnect the system from ac power
to reset the IMM.
2. After 45 seconds, reconnect the
system to the power source and turn
on the system.
3. Run the test again.
4. Make sure that the DSA code is at
the latest level.
5. Make sure that the IMM firmware is
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component.
6. Run the test again.
7. If the failure remains, go to the IBM
website for more troubleshooting
information.
Appendix B. DSA messages
369