Download Print this page

Midea M-Thermal Series Service Manual page 56

Advertisement

 
4.10 H1 Troubleshooting 
Digital display output 
 
 
Description 
 Communication error between outdoor unit main control board and inverter module. 
 M‐Thermal Split stops running. 
 Error code is displayed on outdoor unit main PCB and user interface. 
 
Possible causes 
 Power supply abnormal. 
 Interference from a source of electromagnetic radiation. 
 Outdoor unit main PCB or inverter driven module damaged. 
 
Procedure 
 
LED on the main control board of 
outdoor unit and inverter module are 
Communicatin wires between the main 
control board of outdoor unit and 
inverter module is loose  
There is a source of electromagnetic 
radiation near the unit, such as 
high‐frequency transmitter or other high 
strength radiation device 
Replace outdoor unit main PCB and 
inverter driven module in turn 
 
 
201909                                                                                                                                                                                                                        55 
H1 
     
light  
    No 
    No 
    No 
 
Midea CAC Confidential
 
 
 
LED is not light, the board is 
Yes 
damaged,or have short circuit  
 
Yes 
Reconnect the communicatin wires  
 
Yes 
Remove the source of interference 
 
 
  M‐Thermal Split
 
 
 
 
 
 
 

Hide quick links:

Advertisement

loading