Download Print this page

Midea M-Thermal Series Service Manual page 57

Advertisement

M‐Thermal Split
 
4.11 H6, HH Troubleshooting 
Digital display output 
       
 
Description 
 H6 indicates a DC fan error.   
 HH indicates that H6 protection has occurred 10 times in 2 hours. When HH error occurs, a manual system restart is 
required before the system can resume operation. The cause of HH error should be addressed promptly in order to 
avoid system damage. 
 M‐Thermal Split stops running. 
 Error code is displayed on outdoor unit main PCB and user interface. 
 
Possible causes 
 DC fan wire is loosed.  
 High wind speed. 
 Fan motor blocked or has failed. 
 Invert module damaged. 
 Main PCB is damaged. 
 