  M‐Thermal Split
 
 
 
6.6 Smart grid control 
Unit adjusts the operation according to different electrical signals to realize energy saving.     
 
Free electric energy signal: DHW mode turn on, the setting temperature will be changed to 70℃  automatically, and the 
TBH operate as below:T5<69. the TBH is on, T5  ≥  70, the TBH is off. The unit operate in cooling/heating  mode as the 
normal logic. 
 
Common electric energy signal: unit operates according to users' need.   
 
Expensive electric energy signal: only available for cooling or heating mode and user can set the maximum operating time. 
 
 