Midea M-Thermal Series Service Manual page 35

Advertisement

M‐Thermal Split
 
Table 4‐2.2: MHA‐V4(6,8,10)W/D2N8 outdoor unit main PCB for refrigerant system 
Label in Figure 
4‐2.2 
10 
11 
12 
13 
14 
15 
16 
17 
18 
19 
20 
21 
22 
23 
24 
25 
26 
27 
28 
29 
30 
 
 
 
 
34 
Code 
CN27 
Output port N for invert module PCB 
CN3 
Output port N for hydro‐box control board 
CN31 
Port for ground wire 
CN32 
Port for IC programming 
 
CN37
Port for ground wire 
 
CN10
Input port for neutral wire 
 
CN11
Input port for live wire 
 
SW3
DIP switch 
 
CN24
Input port for +12V/5V 
 
CN13
Port for low pressure switch and high pressure switch 
 
CN8
Port for Tp temp. sensor 
 
CN9
Port for outdoor ambient temp. sensor and condenser temp. sensor 
 
CN1
Port for Th temp. sensor 
 
CN14
Port for TF temp. sensor 
 
CN4
Port for pressure sensor 
 
CN2
Reserved 
 
CN29
Port for communication with hydro‐box control board 
 
CN30
Reserved 
 
CN17
Port for communication with invert module PCB 
 
CN33
Port for electrical expansion value 
 
DSP1
Digital display 
 
CN6
Port for chassis electrical heating tape 
 
CN5
Port for SV6 value 
 
CN6
Port for 4‐way value 
 
CN7
Port for compressor electric heating tape1 
 
CN8
Port for compressor electric heating tape2 
 
CN28
Output port L for invert module PCB 
 
RL2
Output port L for hydro‐box control board 
IC23 
EEPROM 
SW2 
Check button 
 