M‐Thermal Split
 
4.8 HF Troubleshooting 
Digital display output 
 
 
Description 
 Outdoor unit main PCB EEPROM error. 
 M‐Thermal Split stops running. 
 Error code is displayed on outdoor unit main PCB and user interface. 
 
Possible causes 
 Outdoor unit main PCB EEPROM is not connected properly. 
 Outdoor unit main PCB damaged. 
 
Procedure 
 
Outdoor unit EEPROM
Replace outdoor unit main PCB 
 
Notes:   
1.
Outdoor unit EEPROM is designated IC23 on the outdoor unit main PCB (labeled 29 in Figure 4‐2.2 in Part4, 2.3 "Main PCBs for Refrigerant System, Inverter 
Module").   
 
 
52 
HF 
     
1
 is not connected 
properly 
    No 
 
Midea CAC Confidential
 
 
 
Ensure the EEPROM is connected 
Yes 
properly 
 
 
 
 
 
 
   