Air Actuated Single-Point Drain System (Closed Cooling, Inboard Models) - Mercury MerCruiser Service Manual

Hide thumbs Also See for MerCruiser:
Table of Contents

Advertisement

Maintenance
14. Push the locking lever down on the air pump and remove the pump from the air actuator assembly. Install the cap on the
fitting.
15. Install the blue plug on the heat exchanger and tighten securely.
16. The drain system should remain open while transporting the boat or while performing other maintenance. This helps
ensure that all water is drained.
17. Before launching the boat, pull up on the manual release valve. Verify that the green indicators are no longer extended.
18. Open the seacock, if equipped, or unplug and connect the water inlet hose prior to operating the engine.
Air Actuated Single‑Point Drain System (Closed Cooling, Inboard Models)
The following instructions apply to draining procedures performed on engines in vessels that are in the water. For vessels that
are not in the water, you do not need to close the seacock (if equipped) or remove and plug the water inlet hose.
1.
Close the seacock (if equipped) or remove and plug the water inlet hose.
2.
Remove the blue plug from the heat exchanger.
3.
Remove the cap from the air actuated valve assembly.
a
4.
Ensure that the lever on top of the air pump is flush with the handle (horizontal).
5.
Install the air pump on the actuator fitting.
Page 1C-42
a -
Green indicators
a
6135
b
© 2016 Mercury Marine
a -
Blue plug
b -
Cap
55099
90-8M0099748 eng DECEMBER 2015

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2a456613

Table of Contents