Charging System
DMT 2004 Digital Multimeter
V
H z
mV
OFF
A
7.
Start the engine and operate at 1300‑1500 RPM. A DMT reading of more than 0.5 volts indicates excessive resistance in
the wiring.
8.
Connect the DMT negative (–) lead to the alternator ground terminal. Connect the DMT positive (+) lead to the battery
negative (–) post.
9.
Start the engine and operate at 1300–1500 RPM. A DMT reading of more than 0.5 volts indicates excessive resistance in
the wiring.

Sensing and Excitation Circuits

Perform the following tests to ensure that all of the circuits between the alternator and the other components within the charging
system are in good condition.
1.
Unplug the purple and red/pink connector from the alternator.
2.
Connect the positive (+) digital multi‑tester (DMT) lead to the red/pink lead and the negative (–) DMT lead to the ground
terminal.