Mercury MerCruiser Service Manual page 395

Hide thumbs Also See for MerCruiser:
Table of Contents

Advertisement

d.
Disconnect the starboard fuel injector connectors.
a
e.
Remove the two screws securing the oil fill tube and remove the tube.
f.
Disconnect the alternator sense connector, port side post O2 sensor connector and relays.
h h h
g.
Remove the remaining relays and the transom harness connector.
h.
Remove the clean power connector and the OBD‑M MIL light connector.
90-8M0099748 eng DECEMBER 2015
b
d
a
b
c
g
a -
Oil fill tube
b -
Alternator sense connector
c -
Port post O2 sensor connector
d -
Relays
d
c
56515
f
e
56516
© 2016 Mercury Marine
MPI ECT Fuel System
a -
Fuel pump relay
b -
Starter relay
c -
Main power relay
d -
Trim relays
e -
Transom harness
f -
OBD‑M MIL light
g -
Clean power connector
h -
Cable ties
Page 5A-25

Hide quick links: