9 DIAGNOSTICS

This function allows the merchant to perform diagnostic functions to aid in the
maintenance of the terminal.
Step
Terminal Display Description
1.0
2.0
FUNCTION?
3.0
SELF TEST?
ENTER OR CLEAR
4.0
CARD READ TEST?
ENTER OR CLEAR
4.1
SWIPE CARD
4.2
GOOD CARD READ
4.3
BAD CARD READ
5.0
CHIP READ TEST?
ENTER OR CLEAR
5.1
INSERT CARD
5.2
CARD OK
5.3
CARD IS MUTE
5.4
REMOVE CARD
INGENICO Tetra PTS190 Paymark Operating GuideVersion 1.02
Press FUNC.
Enter 9904, press ENTER.
Press ENTER to continue with the self test CLEAR to cancel and return to idle
prompt.
Press ENTER to start CARD READ TEST, CLEAR to bypass CARD READ TEST
or CANCEL to cancel and return to idle prompt.
Swipe a magnetic stripe card through the magnetic stripe card reader. Press
ENTER or CLEAR to go to chip read test.
Displays if the terminal is successful to read the magnetic stripe data.
Displays if the terminal is unable to read the magnetic stripe data.
Press ENTER to start CHIP READ TEST, CLEAR to bypass CHIP READ TEST or
CANCEL to cancel and return to idle prompt.
Insert the chip card into the chip card reader slot in the terminal. Press ENTER or
CLEAR to go to keyboard test.
Displays if the terminal is successful to read the chip card contact.
Displays if the terminal is unable to read the chip card contact.
Remove card from the chip card reader slot.