Download Print this page

Henny Penny Velocity Series Operation Manual page 97

Hide thumbs Also See for Velocity Series:

Advertisement

Program
Display
Code
FC-44
ALWAYS ASK, IS POT
FILLED?
FC-45
ANY FILL: NOT FILLED, EX-
TRA PUMP TIME
Description
This option can be engaged to always ask –
at the end of each Quick Filter, Auto Mix, and
Polish operation, if the pot is filled. Normally,
the control asks IS POT FILLED? only if it
has pumped for a long time attempting to fill
the pot, but no temperature rise was ob-
served on the upper temperature probe.
Press the + or - button to select either YES
or NO.
When refilling the pot at the end of a Quick
Filter, Auto Mix, or Polish operation, the con-
trol closes the drain and runs the pump until
a suitable temperature rise is observed on
the upper temperature probe (the level
probe). If no temperature rise is seen after
pumping for a reasonable maximum pump-
ing time, the control stops, turns the pump
off, and asks IS POT FILLED?.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.