Error
Cause
E-6A MAIN
Temperature probe
TEMP
failure.
PROBE
FAILED
(Open
Circuit)
E-6B MAIN
TEMP
PROBE
FAILED
(Shorted)
E-10 (A
High limit tripped.
thru Y)
E-13A
Pressure transducer
PRES-
failed or unplugged
SURE
SENSOR
FAILED
E-13B
Pressure transducer
PRES-
failed or shprted
SURE
SENSOR
FAILED
E-14
Pressure is to high
PRES-
within the vat.
SURE
TOO HIGH
E-15C
The drain valve
DRAIN
doesn't fully closed.
VALVE
ERROR
E-15P
The drain valve
DRAIN
doesn't fully open.
Correction
Turn the switch to off position, then turn the switch
back to on. If the error persists call for service.
Reset the high limit trip. The reset momentary switch is
below the control panel heat vents, under the lip, above
the condensation tank (box). Perform a clean out, refer
to
6.10 Clean-Out Mode , page
call for service.
T T R R A A I I N N I I N N G G :
E-10 Error explanation.
Call for service.
Call for service.
Perform the
6.7 Cleaning Deadweight - Monthly , page
43
procedure. If the error persists call for service.
Unclog the drain with a drain brush. If the error persists
call for service.
Check drain for an obstruction. If the error persists call
for service.
55. If the error persists
91