Program
Code
FC-19
FC-20
FC-21
80
Display
AUTO TOP OFF: PUMP TIME
AUTO TOP OFF: REPEAT
AUTO TOP OFF: AFTER 'X'
ATTEMPTS, CHECK ATO
Description
TANK messages that occur if the fryer
doesn't detect oil at the proper level after 3
attempts.
Specifies how long the ATO pump runs for
each individual ATO pulse.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
This setting may be manually adjusted as
needed. Ideally, each ATO pulse pumps
about 1/8" (3.175 mm) to 3/16" (5 mm) of
fresh oil into the pot.
Specifies how long the control waits before
assessing the oil level and generating a sec-
ond ATO pulse if the oil level is still low.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
After each ATO pulse, the control monitors
the level probe temperature to see if the oil
has been brought up to the proper level. If
not, a second ATO pulse is given. After a
certain number of pulses, as specified by this
setting, if the oil level still has not been
brought up to the proper level, the control
beeps and displays FILL OIL TANK.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.