Program
Display
Code
FC-22
COOK MODE - FORCED ATO
CHECK AFTER 'X' COOKS
FC-23
START-UP: NEEDED IF TEMP
< 'X'
Phase 2 of the morning startup procedure is to execute the Start-up Mix operation:
drop all of the oil into the drain pan, filter it for a short time, and pump it back into the
vat. This feature is important in thermally mixing the oil to eliminate cold spots and
eliminate the milky oil in the bottom of the pot.
FC-24
START-UP MIX: ENABLED?
3 3 . . Press "X" to return to default or previous
setting.
Controls the number of cook cycles before
forcing a check of the ATO.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
S S t t a a r r t t - - u u p p M M o o d d e e S S e e t t t t i i n n g g s s
If the oil temperature is below 215° F when
the fryer is turned on, the fryer always exe-
cutes a Melt Mode regardless of the Start-up
Needed setting. Sets temperature base to in-
itiate a Start-up.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
There are two choices; Mix or Daily. Mix con-
trols whether or not the Mix operation is per-
formed automatically or manually as part of a
morning start-up. Daily replaces the Mix with
a Daily filter. Some operators may prefer per-
forming a daily filter in the morning instead of
at night. Daily filter is manual only. The unit
prompts for a Daily filter during Start-up if
selected.
Description