Program
Code
FC-7
FC-8
N N O O T T E E :
In a Daily Filter, a FILL operation can be stopped by the user at any time.
For very thin (low viscosity) cooking oils, drain opening setting may need to reduce from
the default value and you might need to reduce the drain opening setting from the default
value.
For 50 Hz systems, or if the control routinely gives up before the pot is refilled, you might
need to increase the max pump time from the default value–50 Hz pumps may run more
slowly than 60 Hz pumps.
FC-9
76
Display
QUICK FILTER: NORMAL FILL
TIME
QUICK FILTER: FILL: NO DE-
TECT: MAX PUMP
D D a a i i l l y y F F i i l l t t e e r r S S e e t t t t i i n n g g s s
DAILY FILTER: DROP OIL:
TIME
Description
3 3 . . Press "X" to return to default or previous
setting.
The expected time it takes to refill the vat at
the end of a Quick Filter.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
If the fryer pumps for this amount of time dur-
ing the Fill phase without observing a tem-
perature rise on the upper temperature
probe, the control turns the pump off, and
asks IS POT FILLED?.
1 1 . . Enter a new value by using the product
numbers.
2 2 . . Press "" to accept the new value.
3 3 . . Press "X" to return to default or previous
setting.
During the Drop cycle, controls the duration
of time the vat drains.
1 1 . . Enter a new value by using the product
numbers.